Cell Register

Building and utility plant

Boilers, refrigeration, compressed air, water treatment, switchgear, building controls and fire and gas systems. A wrong action here can reach the environment and the whole site, and these are the systems most often left on the flat network.

Classes in this family

7; 0 adaptive by default, 5 whose wrong action reaches a person

Zones this family sits in

safetySafety zone: safety controllers, safety scanners and instrumented systems, kept on their own conduit so nothing on the process side can command them. Conduit: safety to line: a safety conduit that carries status out and accepts no command in from the process network.
businessSite business zone: the IT side of the boundary, reached from the plant only through a controlled conduit. Conduit: site business to plant: brokered through the DMZ, jump host and recorded session for anything that reaches down.
lineLine zone: the controllers, drives and stations of one production line, sharing a network and a supervisor. Conduit: line to plant supervisory: the line reports up and takes recipes down through a boundary device with a deny-by-default rule set.
supervisoryPlant supervisory zone: SCADA, historians, HMIs and engineering workstations that see and command many lines. Conduit: plant supervisory to site business: through the industrial DMZ only, no direct session from the office to a controller.

What reaches this family

IEC 62443Attaches to every automated asset the owner runs, in every zone class; the rows differ by zone, by connectivity and by behaviour. Binds Part 2-1 binds the asset owner; Part 3-2 is the owner's zoning and risk assessment; Part 3-3 is what the owner specifies for the system. Part 2-4 binds the service provider and Parts 4-1 and 4-2 the product supplier, so those rows are rendered as what to ask.
SP 800-82Attaches to every asset as the OT-specific overlay: architecture, remote access, patching in OT and incident response. Binds guidance addressed to the operator of the OT environment: it binds nobody in law and is what most OT security programmes are assessed against.
AI ActAttaches only to an adaptive controller or a safety component that is an AI system; a fixed-program machine gets no row, and the page says why. Binds Articles 26 and 4 bind the deployer, which is the asset owner using the system; Articles 12 to 15 bind the provider; a deployer that substantially modifies the system becomes its provider.
Machinery RegulationAttaches to every physical machine and safety component; a controller, a server or a read-only sensor carries no row of its own. Binds the manufacturer of the machine, and whoever substantially modifies it; the owner's row is what to demand at purchase and hold, and what it becomes liable for on a substantial modification.
ISO 27001Attaches the supplier and change controls to every asset and the network controls to every connected one. Binds the organisation that holds the certificate, through the Annex A controls it declared applicable.
Building and utility plantNIST SP 800-82 adds its building automation row here: SP 800-82 SECTOR-2.

Register the assets in this family

Paste the list; every asset in this family is placed in its class, given its zone and SL-T, its behaviour and connectivity, and carries the rows above. Eight assets free, no account.

Build my cell register