Cell Register

SCADA server

Collects data from every controller on site and lets an operator see and command them from one screen.

How the register reads it

Also calledSCADA, historian, supervisory server
FamilyProcess and line control
What a wrong action costsline. A command sent to the wrong controller, or a blind operator when the server is down.
Zone class and SL-Tsupervisory SL-T 3 by default. The plant supervisory zone by definition. Never above 3; the paste may state its own zone name and SL-T.
Networked by defaultYes. It exists to be on the network.
Remote access by defaultYes. Engineering and supplier support are usually remote; the paste decides.
Behaviour by defaultfixed. Configured screens and tags.
Machinery RegulationA controller, a server or a sensor that is not itself a machine or a safety component carries no Machinery Regulation row; the machine it controls does.
Safety references
  • IEC 61508 functional safety of electrical, electronic and programmable electronic systems
  • ISO 12100 risk assessment and risk reduction for machinery
Named, not held: the register does not say whether a machine was built to them.

What each regime attaches, and who it binds

54 clauses across 4 regimes, on the class defaults

Shown on a register for the regimes you tick; with none ticked, the IEC 62443 asset-owner rows are the default. The CRA row is informational on every connected asset. Requirement text drawn from a human-verified compliance corpus under licence: the corpus statement of each clause, not the instrument verbatim.

IEC 62443

Binds Part 2-1 binds the asset owner; Part 3-2 is the owner's zoning and risk assessment; Part 3-3 is what the owner specifies for the system. Part 2-4 binds the service provider and Parts 4-1 and 4-2 the product supplier, so those rows are rendered as what to ask. Source framework: IEC 62443.

Asset owner dutyOn every asset (Part 2-1)
IEC 62443 2-1 AC · 2-1 BCP · 2-1 CSMS · 2-1 IR · 2-1 MOC · 2-1 NSEG · 2-1 PHY · 2-1 PM · 2-1 RA · 2-1 TRN
Whatever the zone, these ten programme duties are the owner's for every asset in the system under consideration.
Asset owner dutySystem requirements to specify for the plant supervisory zone (Part 3-3)
IEC 62443 3-3 SR 1.1 · 3-3 SR 1.2 · 3-3 SR 2.1 · 3-3 SR 2.8 · 3-3 SR 3.1 · 3-3 SR 3.4 · 3-3 SR 5.1 · 3-3 SR 5.2 · 3-3 SR 6.1 · 3-3 SR 6.2 · 3-3 SR 7.3 · 3-3 SR 7.6
The supervisory zone sees and commands many lines and is the zone the office reaches first, so every requirement family applies and continuous monitoring is added.
Asset owner dutyAdded where the asset is on a network
IEC 62443 3-3 SR 3.1 · 3-3 SR 5.2 · 3-3 SR 6.2
Communication integrity, a monitored zone boundary and continuous monitoring attach the moment the asset is reachable.
Asset owner dutyAdded where the asset is reached remotely
IEC 62443 2-1 AC · 3-3 SR 1.1 · 3-3 SR 6.1
The remote account, its authentication and the record of its sessions are the owner's.
Ask the integratorPart 2-4 binds the service provider, not the owner
IEC 62443 2-4 SP-01 · 2-4 SP-02 · 2-4 SP-03 · 2-4 SP-04 · 2-4 SP-05 · 2-4 SP-06
The owner owes none of these rows; the owner asks the integrator and the maintenance provider for the evidence of each before commissioning and at every substantial change.
Ask the supplierPart 4-1 binds the supplier, not the owner
IEC 62443 4-1 DM · 4-1 SG · 4-1 SUM
The owner asks the maker of the controller or the machine for the hardening guide, the vulnerability handling process and the signed update channel.
Ask the supplierPart 4-2 binds the supplier: a networked component
IEC 62443 4-2 CR-1-1 · 4-2 EDR-3-10
For a networked controller the owner also asks for signed firmware with rollback protection and user authentication on the component.

NIST SP 800-82 Rev 3

Binds guidance addressed to the operator of the OT environment: it binds nobody in law and is what most OT security programmes are assessed against. Source framework: NIST SP 800-82 Rev 3.

Asset owner dutyThe OT overlay on every asset
SP 800-82 GOV-3 · HOST-4 · HOST-6 · IR-1 · MON-2
SP 800-82 is guidance for the operator of the OT environment: an inventory that holds firmware and location, safety and security run together, change and patch management, and an incident plan with OT scenarios.
Asset owner dutyNetwork architecture where the asset is on a network
SP 800-82 ARCH-1 · ARCH-2 · NET-1
Zones and conduits, an industrial DMZ between the plant and the office, and deny-by-default rules between zones.
Asset owner dutyRemote access where the asset is reached remotely
SP 800-82 RA-1 · RA-2
A brokered, authenticated, recorded, time-bounded path; vendor accounts named individually and enabled just in time.

The EU Cyber Resilience Act

Binds manufacturers, importers and distributors of products with digital elements; never the owner using them. Source framework: the EU Cyber Resilience Act.

Ask the supplierFrom the application date (the CRA binds manufacturers)
CRA Art. 13 and Annex I · Art. 69, 70, 71
A connected controller or machine with digital elements is a product with digital elements; the manufacturer owes the essential cybersecurity requirements, a support period with security updates and vulnerability handling. The owner asks for the support period and the update channel. Informational: the owner owes no CRA clause.

ISO/IEC 27001:2022

Binds the organisation that holds the certificate, through the Annex A controls it declared applicable. Source framework: ISO/IEC 27001:2022.

Asset owner dutySupplier and change controls on every asset
ISO 27001 5.19 · 5.20 · 5.22 · 8.32
The integrator and the maintenance provider are suppliers; the change to a machine is a change.
Asset owner dutyNetwork controls where the asset is on a network
ISO 27001 5.21 · 8.9 · 8.20 · 8.21 · 8.22
Network security, the services on it, segregation and a secure configuration baseline attach to any connected asset; the ICT supply chain control attaches to what the supplier delivers into it.

The EU AI Act

A fixed-program machine is not an AI system: it does not infer from input how to generate its output and it does not learn or re-plan at runtime. No AI Act row attaches to it; the Machinery Regulation and IEC 62443 do.

Runtime attestation: what to ask the supplier for

Signed firmware and updates with rollback protection, an attested boot or integrity check the controller reports, and behaviour logs that can be read off the device. The register asks; it does not say the supplier provides any of it. CRA Art. 13 and Annex I IEC 62443 3-3 SR 3.3 · 3-3 SR 3.4 · 4-1 SUM · 4-2 EDR-3-10

Ask the integrator

  1. What can reach the server from the office and over what conduit
  2. Which accounts can write to a controller from it
  3. Whether it is patched and how

Findings this class can raise

Do this for every asset on your floor

Paste the list and get this classification for every asset at once, with the zone and SL-T, the behaviour, the connectivity, the findings and the obligation rows per regime. Eight assets free, no account.

Build my cell register

Programmable logic controller · Safety controller